PRODUCTS | BUS CABLES

CANBUS

CANBUS

Application

CAN Bus  (Controller Area Network Bus) Systems are used in data transmission between instruments associated with the host.

Construction
Conductor Stranded electrolytic annealed copper wire
Insulation Foam skin PE | EN 50290-2-23, VDE0207
Colour Code DIN 47100
Lay up Two cores twisted in pair and pairs stranded together
Separator Polyester tape
Foil Screen Aluminium foil 100% coverage 
Screen Tinned copper wire braiding
Outher sheath PVC | EN 50290-2-22 (TM52), VDE0207(YM2)
Outher Sheath Colour RAL 4001 Violet
Specifications
Operating Voltage 250 V 
Test Voltage 1,2 kV 
Mutual Capacitance 55 pF/m
Impedance 110±10 Ω
Loop Resistance (0,22mm2) 190 Ω/km(max.)   (0,50mm2) 78 Ω/km(max.)
Insulation Resistance >2000MΩ.km
Temperature Range -30°C   –   +70°C (fixed)
Min. Bending Radius 10 x  cable diameter
   
Product Code Number of  Cores ×Cross Section (mm)  Cable Diameter (mm ±5%)  Copper Weight (kg/km) Cable Weight (kg/km)
3200000201 1x2x0,22 5,4 9 30
3200000202 2x2x0,22 6 17 42
3200000501 1x2x0,50 6,7 23 57
3200000502 2x2x0,50 7,8 35 73