| Application | ||||
|
Used in multiple devices where system control is provided by transmitting high-speed data from a single center. |
||||
| Construction | ||||
| Conductor | Bare copper wire AWG18 | |||
| Insulation | Foam skin PE | EN 50290-2-23, VDE0207 | |||
| Colour Code | Red-green | |||
| Lay up | Two cores twisted in pair and pairs stranded together | |||
| Separator | Polyester tape | |||
| Foil Screen | Aluminium foil 100% coverage | |||
| Screen | Tinned copper wire braiding | |||
| Outher sheath | PVC | EN 50290-2-22 (TM52), VDE0207(YM2) | |||
| Outher Sheath Colour | RAL 9005 Black | |||
| Specifications | ||||
| Operating Voltage | 250 V | |||
| Test Voltage | 1,2 kV | |||
| Mutual Capacitance | 55 pF/m | |||
| Impedance | 100±15 Ω | |||
| Loop Resistance | 44 Ω/km(max.) | |||
| Insulation Resistance | >2000MΩ.km | |||
| Temperature Range | -30°C – +70°C (fixed) | |||
| Min. Bending Radius | 10 x cable diameter | |||
| Product Code | Number of Cores ×Cross Section (mm) | Cable Diameter (mm ±5%) | Copper Weight (kg/km) | Cable Weight (kg/km) |
| 3200001001 | 1x2x1,00 | 7,5 | 35 | 72 |
| 3200001002 | 2x2x1,00 | 10 | 58 | 115 |
| 3200001010 | 10x2x1,00 | 19 | 215 | 395 |